Solution ID: rd09141998_2764
Last Modified: Nov 27, 2007
Product Category: Devices
Product Area: Programming (CPLD/Config Dev)
Product Sub-area: Programming Software
Device Family: CLASSIC
Title
What is the state of the Turbo Bit if I program a "non-T" Classic™ device with a Programmer Object File (.pof) generated for an EP610T, EP910T, or EP1810T device?
Description
"T" devices have the Turbo Bit permanently set. However, the MAX+PLUS® II software still allows you to turn the Turbo Bit on or off for "T" devices. When compiling a design for a "T" device, the state of the Turbo Bit is specified as on or off in the programming file, but is ignored during programming.
If a non-"T" device is programmed with a programming file that was generated for a "T" device, the non-"T" device's Turbo Bit setting is determined by the setting in the "T" device's original design file.
Feedback
Altera does not warrant that this solution will work for the customer's intended purpose and disclaims all liability for use of or reliance on the solution.