If you are using Concept software on a Sun SPARCstation running SunOS software, you should also install the redifnet EDIF netlist reader utility to convert Concept schematics into MAX+PLUS II-compatible EDIF netlist files. To install the redifnet utility, follow these steps:
- Copy the redifnet directory from the /usr/maxplus2/simlib/concept/edifnet directory to the Cadence system directory.
- Copy the redifnet and pinmap_start files from the /usr/maxplus2/simlib/concept/edifnet/bin directory to the /<Cadence system directory path>/tools/bin.
- Specify the -/usr/maxplus2/simlib/concept/edifnet/max2sim map file as a
PIN_MAP_FILEin the redifnet.cmd file.- (Optional) Modify existing templates for directive files such as compiler.cmd, vloglink.cmd, and global.cmd. These templates are located in the /usr/maxplus2/simlib/concept/edifnet/templates directory.
- (Optional) Modify the expansion.dat and max2sim.map files in the /usr/maxplus2/simlib/concept/edifnet directory.
Feedback
Did this information help you?
If no, please log onto mySupport to file a technical request or enhancement.
Altera does not warrant that this solution will work for the customer's intended purpose and disclaims all liability for use of or reliance on the solution.