Altera Home Page
Literature Licensing
Buy On-Line Download

  Home   |   Products   |   Support   |   End Markets   |   Technology Center   |   Education & Events   |   Corporate   |   Buy On-Line  
  Knowledge Database   |   Devices   |   Design Software   |   Intellectual Property   |   Reference Designs   |   Design Examples   |   mySupport  

 Products
   Quartus II
      SOPC Builder
      MAX+PLUS II
      ModelSim-Altera
  
 Resource Centers
      Overview
      Installation & Licensing
      Scripting
      Board Design & I/O
      Design Entry & Planning
      Synthesis & Netlist Viewers
      Incremental Compilation
      Optimization
      Power Management
   TimeQuest Timing Analyzer
          Clock Analysis
          Exceptions
          Collections
          GUI Features
      Classic Timing Analyzer
      Simulation & Verification
      On-Chip Debugging
      HardCopy Design
  
 Software Resources
      OS Support
      Driver Installation
  
 Download & Licensing
      Download
   Licensing
  
 Quartus II EDA Support
      Quartus II Interface
   Synthesis Tools
   Simulation Tools
   Formal Verification Tools
   Timing Analysis Tools
   Physical Synthesis Tools
   Board Level Tools
  
 Legacy Sw. EDA Support
      View by Vendor
      View by Tool
      View by Function
  

TimeQuest set_multicycle_path Command

By default, the TimeQuest analyzer uses a single-cycle analysis. When analyzing a path, the setup launch and latch edge times are determined by finding the closest two active edges in the respective waveforms. For a hold analysis, the timing analyzer analyzes the path against two timing conditions for every possible setup relationship (not just the worst-case). Therefore, the hold launch and latch times may be completely unrelated to the setup launch and latch edges.

A multicycle constraint relaxes setup or hold relationships by the specified number of clock cycles based on the source (-start) or destination (-end) clock. An end multicycle constraint of 2 extends the worst-case setup latch edge by one destination clock period.

Hold multicycle constraints are based on the default hold position (the default value is 0). An end hold multicycle constraint of 1 effectively subtracts one destination clock period from the default hold latch edge. You can use the set_multicycle_path command to specify the multicycle constraints in the design. The following list shows the set_multicycle_path command including the available options:

set_multicycle_path
     [-setup | -hold]
     [-start | -end]
     [-from <from list>]
     [-to <to list>]
     [-thru <thru list>]
     <path multiplier>

Table 1 describes the options for the set_multicycle_path command.

Table 1. Options Description for set_false_path Command
Option Description
-setup | -hold Specifies the type of multicycle to be applied.
-start | -end Specifies whether the start or end clock acts the source or destination for the multicycle.
-from <from list> The <from list> is a collection or list of objects in the design. The <from list> acts as the start point of the path.
-to <to list> The <to list> is a collection or list of objects in the design. The <to list> acts as the end point of the path.
-thru <thru list> The <thru list> is a collection or list of objects in the design. The <thru list> acts as the thru point of the path.
<path multiplier> Specifies the multicycle multiplier value.

When the objects are timing nodes, the multicycle constraint only applies to the path between the two nodes. When an object is a clock, the multicycle constraint applies to all paths where the source node (for - from) or destination node (for -to) is clocked by the clock.