Article ID: 000075377 Content Type: Troubleshooting Last Reviewed: 01/11/2023

Why does the Intel® Stratix® 10 Low Latency 10G Ethernet MAC Example Designs fail to simulate when using NCSim or Xcelium?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Low Latency Ethernet 10G MAC Intel® FPGA IP
  • 10GBASE-R PHY Intel® FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    The Intel® Stratix® 10 Low Latency 10G Ethernet MAC Example Designs will fail to simulate correctly in either NCSim or Xcelium for the configurations below:

    • 10G Base-R
    • 1/2.5/10G with 1588
    • 10M/100M/1G/2.5G/10G
    Resolution

    No workaround for NCSim or Xcelium is available.

    Please use VCS or ModelSim to simulate this IP core with software version v17.1 or v18.0

    The simulation problem when using NCSim or Xcelium is scheduled to be fixed in a future version of Intel Quartus® Prime Pro Edition Software.

    Related Products

    This article applies to 3 products

    Intel® Stratix® 10 GX FPGA
    Intel® Stratix® 10 SX SoC FPGA
    Intel® Stratix® 10 FPGAs and SoC FPGAs