Description
Due to a missing line in the simulation script generated by the Stratix® V CUSTOM_PHY IP Megawizard in Quartus II Software Version 10.1-SP1 you will see the following error in Modelsim.
# Error in macro .\modelsim_example_script.tcl
# can't read "language": no such variable
# while executing
# "if { == "verilog"}
To workaround this error, insert the following at line 68.
"set language verilog"