Article ID: 000079110 Content Type: Troubleshooting Last Reviewed: 09/11/2012

Why does my design containing C2H accelerators timeout immediately even though I am using an Opencore evaluation?

Environment

  • Nios® II Processor
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    If you do not have a C2H Compiler license and close the OpenCore Plus status box while running a design containing a C2H accelerator, the design times out immediately rather than allowing the one hour grace period.

    To workaround the problem, remain tethered to the development board during evaluation and do not close the OpenCore Plus status box. Alternatively, you can purchase a C2H Compiler license.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices