Article ID: 000074259 Content Type: Install & Setup Last Reviewed: 06/30/2014

Why does sof2flash, elf2flash,elf2hex and bin2flash fail when run on a Windows PC?

Environment

  • Quartus® II Subscription Edition
  • All

    BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Quartus II software® version 13.1,  some of the NIOS® II EDS utilities may fail with no error output or messages when run on a Windows PC.

    The affected utilities are: sof2flash, elf2flash, elf2hex and bin2flash

     

    Resolution

    To work around this problem in the Quartus II software version 13.1 on Windows:

    • After opening the NIOS II Terminal, set an environment varibable called QUARTUS_BINDIR to /bin
      • export QUARTUS_BINDIR=/bin
    • Open the Nios II Command Shell from Qsys via the Tools menu, then run the required utility
    • Run the required utility from a Linux installation of the Quartus II software version 13.1

    This problem is currently scheduled to be fixed in a future version of the Quartus II software, and this solution will be updated as other workarounds are finalised.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices