Article ID: 000084575 Content Type: Error Messages Last Reviewed: 01/19/2015

Internal Error: Sub-system: CSETQ, File: /quartus/saui/csetq/csetq_more_settings.cpp, Line: 425 Cannot insert a blank Option Value into list.

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description Due to a problem in the Quartus® II software version 14.0, setting the “location of user compiled simulation library” to blank causes the above error. Steps to reproduce:
    1. On the Assignments menu, select Settings.
    2. In the EDA Tools Settings, select Simulation.
    3. In the More EDA netlist writer settings, select Location of user compiled simulation library.
    4. Add in the path and select OK.
    5. Reopen the Location of user compiled simulation library
    6. Delete the path and you will see the above error.
    Resolution

    To work around this problem, do not set the location of user compiled simulation library to blank.

    This problem is fixed beginning with the Quartus II software version 14.1

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices