Article ID: 000074908 Content Type: Product Information & Documentation Last Reviewed: 09/11/2012

How can I calculate the Failure In Time (FIT) rate across temperature for an Altera device?

Environment

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

The correct method is to use the acceleration factor equation from the Reliability Report (PDF):

 

Temperature Acceleration Factor = exp[Ea/((k)(Toperation)) - Ea/((k)(Tstress))]