Article ID: 000076028 Content Type: Error Messages Last Reviewed: 09/22/2011

Internal Error When Double-Clicking on a Large Objdump File

Environment

  • Quartus® II Subscription Edition
  • All

    BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    On Windows when opening a large objdump file in the Nios II IDE, you might get the following error message:

    Unable to create this part due to an internal error. Reason for the failure: Editor could not be initialized.
    Resolution

    Adjust the Windows launch arguments for the Nios II IDE editor. Perform the following steps:

    1. On the Windows Start menu, browse to the Nios II EDS program icon, right-click it, then click Properties. The Windows Properties dialog box appears.
    2. In the Target field, append "vmargs -Xmx1024m" to the end of the path to the Nios II IDE executable. For example:
    C:\altera\72\nios2eds\bin\eclipse\nios2-ide.exe -vmargs -Xmx1024m

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices