Article ID: 000086259 Content Type: Error Messages Last Reviewed: 04/13/2018

Error (12077): Node instance "altera_mult_add_rtl2" instantiated with unknown parameter "<name>"

Environment

  • Intel® Quartus® Prime Standard Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Standard Edition software version 17.1 Update 1 and earlier, while using altmult_complex IP in VHDL you may see the following error messages in message window when you run Analysis & Synthesis.

    Error (12077): Node instance "altera_mult_add_rtl2" instantiated with unknown parameter "ACCUM_SLOAD_PIPELINE_SCLR"

    Error (12077): Node instance "altera_mult_add_rtl2" instantiated with unknown parameter "ADDNSUB_MULTIPLIER_PIPELINE_SCLR1"

    Error (12077): Node instance "altera_mult_add_rtl2" instantiated with unknown parameter "ADDNSUB_MULTIPLIER_PIPELINE_SCLR3"

    Error (12077): Node instance "altera_mult_add_rtl2" instantiated with unknown parameter "SIGNED_PIPELINE_SCLR_A"

    Error (12077): Node instance "altera_mult_add_rtl2" instantiated with unknown parameter "SIGNED_PIPELINE_SCLR_B"

     

     

    Resolution

    To work around this problem, remove these ports from the <IP_Name>.vhd file.

    This problem is scheduled to be fixed in a future release of the Intel Quartus Prime Standard Edition software.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices