Summary
Summary:
Potential security vulnerabilities in the Intel® FPGA SDK for OpenCL™ Intel® Quartus® Prime Pro software may allow escalation of privilege. Intel is releasing software updates to mitigate these potential vulnerabilities.
Vulnerability Details:
CVEID:
CVE-2022-37329
Description: Uncontrolled search path in some Intel® Quartus® Prime Pro and Standard Edition software may allow an authenticated user to potentially enable escalation of privilege via local access.
CVSS Base Score: 6.7 Medium
CVSS Vector: CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H
CVEID: CVE-2022-34157
Description: Improper access control in the Intel® FPGA SDK for OpenCL™ with Intel® Quartus® Prime Pro Edition software before version 22.1 may allow authenticated user to potentially enable escalation of privilege via local access.
CVSS Base Score: 6.7 Medium
CVSS Vector: CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H
Affected products:
Intel® FPGA SDK for OpenCL™ with Intel® Quartus® Prime Pro Edition software before version 22.1.
Intel® Quartus® Prime Pro Edition software before version 21.3.
Intel® Quartus® Prime Standard Edition software before version 21.1.
Recommendations:
Intel recommends updating to the versions below.
Intel® Quartus® Prime Pro Edition software to version 21.3 or later at:
Intel® Quartus® Prime Standard Edition Design Software to version 21.1 or later at:
Intel® FPGA SDK for OpenCL™ Pro Edition to version 22.1 or later at:
Acknowledgements:
Intel would like to thank Marius Gabriel Mihai, Intel employee CVE-2022-37329, CVE-2022-34157.
| Revision | Date | Description |
|---|---|---|
| 1.0 | 02/14/2023 | Initial Release |
| 1.1 | 05/06/2026 | Transfer Advisory to Altera. |
Legal Notices and Disclaimers
Altera provides these materials as-is, with no express or implied warranties. All products, dates, and figures specified are preliminary based on current expectations, and are subject to change without notice.
Altera products and services described may contain design defects or errors known as errata, which may cause the product to deviate from published specifications. Current characterized errata are available on request. Altera products that have met their End of Servicing Updates may no longer receive functional and security updates.
Altera technologies’ features and benefits depend on system configuration and may require enabled hardware, software, or service activation. Performance varies depending on system configuration. No product or component can be absolutely secure. Check with your system manufacturer or retailer or learn more at https://www.altera.com.
Some results may have been estimated or simulated using internal Altera analysis or architecture simulation or modeling and are provided for informational purposes only. Any differences in your system hardware, software, or configuration may affect your actual performance. © Altera Corporation.
Altera, the Altera logo, and other Altera marks are trademarks of Altera Corporation in the United States and other countries. Other names and brands may be claimed as the property of others.