PSIRT Advisory – ASA-0003

High Level Synthesis Compiler Security Advisory

CVE Affected Products Affected Versions Fixed Version
CVE-2025-13669 High Level Synthesis Compiler Up to 24.3 N/A
CVE-2025-13670 High Level Synthesis Compiler Up to 24.3 N/A

ASA-0003

Summary:
A potential security vulnerability in High Level Synthesis Compiler Software may allow escalation of privilege.

CVE ID: CVE-2025-13669

Vulnerability Details:
A Current Working Directory (CWD) DLL planting vulnerability exists in a batch file in a design example.

Mitigations and Recommendations:
Altera recommends replacing the build.bat with the file located here. This is a Windows Issue. The Linux version is not affected.

Description/CWE: CWE-427: Uncontrolled Search Path Element

CVSS Base Score 6.7 Severity Medium

CVSS Vector 3.1: CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H

CVSS Base Score 4.0: 5.4 Medium CVSS

Vector 4.0: CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVE ID: CVE-2025-13670

Vulnerability Details:
The High Level Synthesis Compiler i++ command for Windows is vulnerable to a DLL planting vulnerability. The Linux version is not affected.

Mitigations and Recommendations:
To mitigate the issue, Altera recommends restricting write access to the directory “C:\quartus\bin64" to system administrators only

Description/CWE: CWE-427: Uncontrolled Search Path Element

CVSS Base Score 6.7 Severity Medium

CVSS Vector 3.1: CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H

CVSS Base Score 4.0: 5.4 Medium CVSS

Vector 4.0: CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Acknowledgements:
Altera would like to thank ycdxsb for reporting these issues

Revision Date Affected Versions
1.0 05/13/2025 Initial Release
1.1 12/20/2025 Add CVE Numbers

Legal Notices and Disclaimers

Altera provides these materials as-is, with no express or implied warranties. All products, dates, and figures specified are preliminary based on current expectations, and are subject to change without notice.

Altera products and services described may contain design defects or errors known as errata, which may cause the product to deviate from published specifications. Current characterized errata are available on request. Altera products that have met their End of Servicing Updates may no longer receive functional and security updates.

Altera technologies’ features and benefits depend on system configuration and may require enabled hardware, software, or service activation. Performance varies depending on system configuration. No product or component can be absolutely secure. Check with your system manufacturer or retailer or learn more at https://www.altera.com.

Some results may have been estimated or simulated using internal Altera analysis or architecture simulation or modeling and are provided for informational purposes only. Any differences in your system hardware, software, or configuration may affect your actual performance. © Altera Corporation.

Altera, the Altera logo, and other Altera marks are trademarks of Altera Corporation in the United States and other countries. Other names and brands may be claimed as the property of others.