PSIRT Advisory – ASA-0004

Quartus® Prime Pro Security Advisory

CVE Affected Products Affected Versions Fixed Version
CVE-2025-14596 Quartus® Prime Pro Edition Installer (SFX) for Windows 24.1–24.3.1 25.1
CVE-2025-14605 Quartus® Prime Pro Edition Programmer and Tools Quartus® Prime Pro Edition (System Console utility) 17.0–25.1 25.1.1
CVE-2025-14612 Quartus® Prime Pro Edition Installer (SFX) for Windows 24.1–25.1.1 25.3

ASA-0004

CVE ID: CVE-2025-14596

A potential security vulnerability in Quartus Prime Pro Edition Installer (SFX) for Windows may allow escalation of privilege.

Vulnerability Details:
The Quartus Prime Pro Edition Installer (SFX) for Windows is vulnerable to a binary planting attack. The Linux version is not affected.

Mitigations and Recommendations:
Altera recommends using the Quartus 25.1 Pro Edition installer or later. For older Quartus Prime Pro versions, downloading the individual installation files directly from the download page avoids the problem. Individual installer files are not affected.

Description/CWE: CWE-427: Uncontrolled Search Path Element

CVSS Base Score 6.7 Severity Medium

CVSS Vector 3.1: CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H

CVSS Base Score 4.0: 5.4 Medium CVSS

Vector 4.0: CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVE ID: CVE-2025-14605

A potential security vulnerability in the System Console utility included in the Quartus Prime Pro Edition for Windows may allow escalation of privilege.

Vulnerability Details:
The System Console utility included in the Quartus Prime Pro Edition for Windows is vulnerable to a Current Working Directory (CWD) planting attack. The Linux version is not affected. The System Console utility included in the Quartus Prime Pro Edition Programmer and Tools for Windows is also affected.

Mitigations and Recommendations:
Altera recommends using the System Console utility included in Quartus 25.1.1 Pro Edition or later, or the one included in Quartus Prime Pro Edition Programmer and Tools 25.1.1 or later.

Description/CWE: CWE-427: Uncontrolled Search Path Element

CVSS Base Score 6.7 Severity Medium

CVSS Vector 3.1: CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H

CVSS Base Score 4.0: 5.4 Medium CVSS

Vector 4.0: CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVE ID: CVE-2025-14612

A potential security vulnerability in Quartus Prime Pro Edition Installer (SFX) for Windows may allow escalation of privilege.

Vulnerability Details:
The Quartus Prime Pro Edition Installer (SFX) for Windows is vulnerable to a binary planting attack. The Linux version is not affected.

Mitigations and Recommendations:
Altera recommends using the Quartus 25.3 Pro Edition installer or later. For older Quartus Prime Pro versions, downloading the individual installation files directly from the download page avoids the problem. Individual installer files are not affected.

Description/CWE: CWE-377: Insecure Temporary File

CVSS Base Score 6.7 Severity Medium

CVSS Vector 3.1: CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H

CVSS Base Score 4.0: 5.4 Medium CVSS

Vector 4.0: CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Acknowledgements:
Altera would like to thank sim0nleehkhk (CVE-2025-14596) for reporting this issue.

Revision Date Affected Versions
1.0 12/20/2025 Initial Release

Legal Notices and Disclaimers

Altera provides these materials as-is, with no express or implied warranties. All products, dates, and figures specified are preliminary based on current expectations, and are subject to change without notice.

Altera products and services described may contain design defects or errors known as errata, which may cause the product to deviate from published specifications. Current characterized errata are available on request. Altera products that have met their End of Servicing Updates may no longer receive functional and security updates.

Altera technologies’ features and benefits depend on system configuration and may require enabled hardware, software, or service activation. Performance varies depending on system configuration. No product or component can be absolutely secure. Check with your system manufacturer or retailer or learn more at https://www.altera.com.

Some results may have been estimated or simulated using internal Altera analysis or architecture simulation or modeling and are provided for informational purposes only. Any differences in your system hardware, software, or configuration may affect your actual performance. © Altera Corporation.

Altera, the Altera logo, and other Altera marks are trademarks of Altera Corporation in the United States and other countries. Other names and brands may be claimed as the property of others.